Item# PA-10950

PROACTIVE ENVIRONMENTAL PRODUCTS®

Low Flow with Power Booster 4 Controller

Engineered specifically for Proactive Environmental Products Int'l®

12-volt Abyss 300  and the 12-volt Abyss 300 Slimline Plastic Pumps

 

The Proactive® Low Flow with Power Booster 4 Controller is engineered specifically for the 12-volt Abyss 300® and the 12-volt Abyss 300 Slimline® plastic pumps. This device will allow the user to regulate low flow sampling (Fractional Flow®) as low as 40ml/min. Simply connect the booster to a 12 volt deep cycle battery and connect the pump to the booster and stand back for awesome pumping power!

 

Check out all the great features of the Low Flow with Power Booster 4 Controller

 

  • Engineered with reverse polarity protection

  • Heavy duty steel weatherproof case

  • Low voltage disconnect (LVD) at 10.75 volts (turns off controller or allows pump to pulsate)

  • Constant Voltage Boosting Technology (CVBT) allows the correct voltage to reach the pump motors

  • 30 AMP "safety" fuse to protect electronics and user

  • 6 month parts and labor warranty

  • 'Ramp Up' control dial

  • 3.5 foot wire lead to battery clamps and 4 foot wire leads to pump connector

  • Steel handle for comfort and control

 

The Abyss 300 is a registered trademark ®

Low Flow with Power Booster 4 Controller

Requires one of the following Plastic Pumps:

  Pumping Depth in Feet             Gallons Per Minute    

   DTW (Depth To Water)       At 12.5 Volts At The Source

 

                 10                                         2.00

                 20                                         2.00

                 40                                         1.75

                 60                                         1.75

                 80                                         1.75

               100                                         1.50

               120                                         1.50

     

               140                                         1.50

               160                                         1.50

               180                                         1.25

               200                                         1.25

               220                                         1.00

               240                                         1.00

               260                                         1.00

               280                                         00.5

               300                                         00.5

 

 

Test was conducted with a 12 volt deep cycle battery

at 12.5 volts at battery terminals

 

Running your vehicle while using this pump

will dramatically increase purge volume

State Groundwater Monitoring Well Sampling Procedures:

  • Alabama Groundwater Monitoring Well Sampling Procedures

  • Alaska Groundwater Monitoring Well Sampling Procedures

  • Arizona Groundwater Monitoring Well Sampling Procedures

  • Arkansas Groundwater Monitoring Well Sampling Procedures

  • California Groundwater Monitoring Well Sampling Procedures

  • Colorado Groundwater Monitoring Well Sampling Procedures

  • Connecticut Groundwater Monitoring Well Sampling Procedures

  • Delaware Groundwater Monitoring Well Sampling Procedures

  • Florida Groundwater Monitoring Well Sampling Procedures

  • Georgia Groundwater Monitoring Well Sampling Procedures

  • Hawaii Groundwater Monitoring Well Sampling Procedures

  • Idaho Groundwater Monitoring Well Sampling Procedures

  • Illinois Groundwater Monitoring Well Sampling Procedures

  • Indiana Groundwater Monitoring Well Sampling Procedures

  • Iowa Groundwater Monitoring Well Sampling Procedures

  • Kansas Groundwater Monitoring Well Sampling Procedures

  • Kentucky Groundwater Monitoring Well Sampling Procedures

  • Louisiana Groundwater Monitoring Well Sampling Procedures

  • Maine Groundwater Monitoring Well Sampling Procedures

  • Maryland Groundwater Monitoring Well Sampling Procedures

  • Massachusetts Groundwater Monitoring Well Sampling Procedures

  • Michigan Groundwater Monitoring Well Sampling Procedures

  • Minnesota Groundwater Monitoring Well Sampling Procedures

  • Mississippi Groundwater Monitoring Well Sampling Procedures

  • Missouri Groundwater Monitoring Well Sampling Procedures

  • Montana Groundwater Monitoring Well Sampling Procedures

  • Nebraska Groundwater Monitoring Well Sampling Procedures

  • Nevada Groundwater Monitoring Well Sampling Procedures

  • New Hampshire Groundwater Monitoring Well Sampling Procedures

  • New Jersey Groundwater Monitoring Well Sampling Procedures

  • New Mexico Groundwater Monitoring Well Sampling Procedures

  • New York Groundwater Monitoring Well Sampling Procedures

  • North Carolina Groundwater Monitoring Well Sampling Procedures

  • North Dakota Groundwater Monitoring Well Sampling Procedures

  • Ohio Groundwater Monitoring Well Sampling Procedures

  • Oklahoma Groundwater Monitoring Well Sampling Procedures

  • Oregon Groundwater Monitoring Well Sampling Procedures

  • Pennsylvania Groundwater Monitoring Well Sampling Procedures

  • Rhode Island Groundwater Monitoring Well Sampling Procedures

  • South Carolina Groundwater Monitoring Well Sampling Procedures

  • South Dakota Groundwater Monitoring Well Sampling Procedures

  • Tennessee Groundwater Monitoring Well Sampling Procedures

  • Texas Groundwater Monitoring Well Sampling Procedures

  • Utah Groundwater Monitoring Well Sampling Procedures

  • Vermont Groundwater Monitoring Well Sampling Procedures

  • Virginia Groundwater Monitoring Well Sampling Procedures

  • Washington Groundwater Monitoring Well Sampling Procedures

  • West Virginia Groundwater Monitoring Well Sampling Procedures

  • Wisconsin Groundwater Monitoring Well Sampling Procedures

  • Wyoming Groundwater Monitoring Well Sampling Procedures

Copyright 2017 Proactive Environmental Products International LLC®. All rights Reserved.