Item# P-10100

PROACTIVE ENVIRONMENTAL PRODUCTS®

12 Volt Cyclone® Plastic Pump

(Lifts 25 Feet / 8 Meters DTW)

The Engineered Plastic 12-volt submersible centrifugal Cyclone® pump is capable of pumping up to 25 feet from ground level (DTW)* by simply connecting the Cyclone® to a 12-volt deep cycle battery. Its reliable design is perfect for continuous sampling and purging of groundwater wells and Low Flow Sampling (Fractional Flow®).

 

The 12 Volt Cyclone® is ideal for low flow sampling (Fractional Flow®) in conjunction with Proactive Environmental Products Low Flow Sampling Controller. Low flow sample all the way down to 40 mL/s per minute. To achieve even a lower flow.... simply add the Low Flow Sampling Control Valve in conjunction with the Low Flow Sampling controller to achieve flow rates of 10 mL/s per minute or less!

 

Simplify and Expedite Your Next Sampling Event!

  • The Cyclone® can operate under harsh conditions and higher turbidity.

 

  • The Cyclone® can run continuously in water without the need for a cool down!

 

  • The Cyclone® has a 400-hour motor life!

 

  • The Cyclone® has a sleek outside that minimizes well hang-ups.

 

  • The Cyclone® is a very reliable and economical pump that provides a great bang for your buck!

 

This pump is not engineered to be dedicated in the physical liquid 24 hours a day.

 

* Depth to water

Specifications:

POWER CONSUMPTION:                 60 WATTS (MAX)

VOLT RECOMMENDATION:              12-15 DC (direct current) At Source

MAXIMUM AMP OUTPUT:               4 AMPS

MEASUREMENTS:                            LENGTH 7" / DIAMETER: 1.82"

REQUIRED TUBING:                         3/8" or 1/2" ID TUBING

SUPPLIED WITH:                             35 FEET OF HEAVY DUTY 12 GAUGE WIRE, QUICK                                                                                                  DISCONNECT PLUG & BATTERY CLAMPS

PUMP CONSTRUCTION:                    ABS

IMPELLER CONSTRUCTION:              POLY ACETAL (POM)

MOTOR SHAFT CONSTRUCTION:       STAINLESS STEEL 

WIRE CONSTRUCTION:                     PVC

SEAL CONSTRUCTION:                      NITRILE  

 Pumping Depth in Feet                Gallons Per Minute    

  DTW (Depth To Water)         At 12.5 Volts At The Source

 

                3                                             2.0

              

              10                                             1.0

              20                                             .35

                

              25                                             .25

              30                                             N/A

 

 

Test was conducted with a 12 volt deep cycle battery

at 12.5 volts at battery terminals

 

 Running your vehicle while using this pump

will dramatically increase purge volume

OPTIONAL:

ACCESSORIES:

State Groundwater Monitoring Well Sampling Procedures:

  • Alabama Groundwater Monitoring Well Sampling Procedures

  • Alaska Groundwater Monitoring Well Sampling Procedures

  • Arizona Groundwater Monitoring Well Sampling Procedures

  • Arkansas Groundwater Monitoring Well Sampling Procedures

  • California Groundwater Monitoring Well Sampling Procedures

  • Colorado Groundwater Monitoring Well Sampling Procedures

  • Connecticut Groundwater Monitoring Well Sampling Procedures

  • Delaware Groundwater Monitoring Well Sampling Procedures

  • Florida Groundwater Monitoring Well Sampling Procedures

  • Georgia Groundwater Monitoring Well Sampling Procedures

  • Hawaii Groundwater Monitoring Well Sampling Procedures

  • Idaho Groundwater Monitoring Well Sampling Procedures

  • Illinois Groundwater Monitoring Well Sampling Procedures

  • Indiana Groundwater Monitoring Well Sampling Procedures

  • Iowa Groundwater Monitoring Well Sampling Procedures

  • Kansas Groundwater Monitoring Well Sampling Procedures

  • Kentucky Groundwater Monitoring Well Sampling Procedures

  • Louisiana Groundwater Monitoring Well Sampling Procedures

  • Maine Groundwater Monitoring Well Sampling Procedures

  • Maryland Groundwater Monitoring Well Sampling Procedures

  • Massachusetts Groundwater Monitoring Well Sampling Procedures

  • Michigan Groundwater Monitoring Well Sampling Procedures

  • Minnesota Groundwater Monitoring Well Sampling Procedures

  • Mississippi Groundwater Monitoring Well Sampling Procedures

  • Missouri Groundwater Monitoring Well Sampling Procedures

  • Montana Groundwater Monitoring Well Sampling Procedures

  • Nebraska Groundwater Monitoring Well Sampling Procedures

  • Nevada Groundwater Monitoring Well Sampling Procedures

  • New Hampshire Groundwater Monitoring Well Sampling Procedures

  • New Jersey Groundwater Monitoring Well Sampling Procedures

  • New Mexico Groundwater Monitoring Well Sampling Procedures

  • New York Groundwater Monitoring Well Sampling Procedures

  • North Carolina Groundwater Monitoring Well Sampling Procedures

  • North Dakota Groundwater Monitoring Well Sampling Procedures

  • Ohio Groundwater Monitoring Well Sampling Procedures

  • Oklahoma Groundwater Monitoring Well Sampling Procedures

  • Oregon Groundwater Monitoring Well Sampling Procedures

  • Pennsylvania Groundwater Monitoring Well Sampling Procedures

  • Rhode Island Groundwater Monitoring Well Sampling Procedures

  • South Carolina Groundwater Monitoring Well Sampling Procedures

  • South Dakota Groundwater Monitoring Well Sampling Procedures

  • Tennessee Groundwater Monitoring Well Sampling Procedures

  • Texas Groundwater Monitoring Well Sampling Procedures

  • Utah Groundwater Monitoring Well Sampling Procedures

  • Vermont Groundwater Monitoring Well Sampling Procedures

  • Virginia Groundwater Monitoring Well Sampling Procedures

  • Washington Groundwater Monitoring Well Sampling Procedures

  • West Virginia Groundwater Monitoring Well Sampling Procedures

  • Wisconsin Groundwater Monitoring Well Sampling Procedures

  • Wyoming Groundwater Monitoring Well Sampling Procedures

Copyright 2017 Proactive Environmental Products International LLC®. All rights Reserved.